Product details
Overview
The Bently Nevada 3300 XL 11 mm Extension Cable (Product No. 330730-080-00-00) is an essential accessory designed to ensure reliable connectivity between Bently Nevada 3300 XL Proximity Probes and monitoring systems. Manufactured in the U.S.A, this extension cable offers high durability, with options for both standard and armored protection. The flexible AISI 302 stainless steel (SST) armor with an FEP outer jacket provides additional protection, making it suitable for harsh industrial environments. Furthermore, it is available in a length of 8.0 meters (26.2 feet), offering optimal flexibility for varied installation scenarios.
Technical Specifications
- Brand: Bently Nevada
- Model: 3300 XL 11 mm Extension Cable- 330730-080-00-00
- Cable Capacitance: 69.9 pF/m (21.3 pF/ft) typical
- Extension Cable Armor: Optional AISI 302 SST with FEP outer jacket
- Operating Temperature Range: -51°C to +177°C (-60°F to +351°F)
- Storage Temperature Range: -51°C to +177°C (-60°F to +351°F)
- Cable Weight: 45 g/m (0.5 oz/ft) for standard, total 0.36kg
- Extension Cable Material: 75 ⦠triaxial, fluoroethylene propylene (FEP) insulated
- Tensile Strength: 330 N (75 lbs) from probe case to probe lead; 270 N (60 lbs) at the probe lead to extension cable connectors
- Connector Material: Gold-plated brass
- Capacitance: 69.9 pF/m (21.3 pF/ft) typical
Ordering Information
- Product Number: 330730-080-00-00
- Cable Length: 8.0 meters (26.2 feet)
- Connector and Cable Option: Standard cable (00)
- Agency Approval Option: Not required (00)
- Armor Option: Flexible AISI 302 SST with FEP outer jacket (optional)
FAQ
- Q1: Can I use the 3300 XL Extension Cable in high-temperature environments?
Yes, this extension cable operates in temperatures ranging from -51°C to +177°C (-60°F to +351°F), making it suitable for extreme conditions. - Q2: Does the extension cable come with armor?
The extension cable can be ordered with optional flexible AISI 302 stainless steel (SST) armor for extra protection. - Q3: What is the recommended gap setting for the 3300 XL Probe?
The recommended gap setting for the 3300 XL Probe is 2.5 mm (100 mils).
For more detailed information: 3300 XL 11 mm Proximity Transducer System Datasheet