Product details
Overview
The Bently Nevada 3300 XL 8 mm Reverse Mount Probe (Product No. 330105-02-12-90-12-CN) is designed for high-precision vibration monitoring. It features robust construction with advanced materials and technology to ensure excellent performance in challenging industrial environments.
Key Features:
- Product Type: 3300 XL 8 mm Reverse Mount Probes
- Manufacturer: Bently Nevada
- Made In: U.S.A
- Certificate of Origin (COO): Available upon request
- Probe Tip Material: Polyphenylene sulfide (PPS)
- Probe Case Material: AISI 303 or 304 stainless steel (SST)
- Weight: 0.323 kg
- Dimensions: 20.4 cm x 22.2 cm x 3.7 cm
- Connector: 12 Miniature ClickLoc coaxial connector with FluidLoc cable option
- Temperature Range:
- Standard: -52Ā°C to +177Ā°C (-62Ā°F to +350Ā°F)
- Extended: -52Ā°C to +218Ā°C (-62Ā°F to +425Ā°F) for probe tip; -51Ā°C to +260Ā°C (-60Ā°F to +500Ā°F) for cable and connector
- Maximum Thread Engagement Length: 0.563 inches (3/8-24 UNF threads)
- Nominal Probe DC Resistance (9.0 m): 9.87 Ā± 0.50 Ī©
- Country-Specific Approval: CN (China)
Technical Specifications:
- Part Number: 330105-02-12-90-12-CN
- Threads: 3/8-24 UNF
- Total Length Option: 9.0 meters (29.5 feet)
- Minimum Target Size: 15.2 mm (0.6 in) diameter flat target
- Probe Tip & Case Materials:
- Tip: Polyphenylene sulfide (PPS)
- Case: AISI 303/304 stainless steel
- Cable Option: FluidLoc cable option available, prevents leakage of fluids
- Performance Characteristics:
- Accuracy applies to systems with AISI 4140 steel targets
- TipLoc molding and CableLoc designs enhance durability
- Rated pull strength: 330 N (75 lbf)
- Maximum cable torque: 22.6 Nā¢m (200 inā¢lbf), recommended torque: 7.5 Nā¢m (66 inā¢lbf)
Extended Temperature Range Probe:
- For probe tip: -52Ā°C to +218Ā°C (-62Ā°F to +425Ā°F)
- For probe cable and connector: -51Ā°C to +260Ā°C (-60Ā°F to +500Ā°F)
FAQs:
- What is the fluidLoc cable option used for?
- The FluidLoc cable prevents oil and other liquids from leaking out of the machine through the cableās interior. It is typically not required unless specified for the application.
- What are the maximum operating temperatures?
- The standard probe supports a temperature range from -52Ā°C to +177Ā°C, while the extended temperature range option allows operation up to +218Ā°C for the probe tip and +260Ā°C for the cable and connector.
- What is the recommended torque for installation?
- The maximum rated torque for the probe installation is 22.6 Nā¢m, with the recommended torque being 7.5 Nā¢m.
- What is the minimum target size required for the probe?
- The minimum target size for proper function is 15.2 mm (0.6 in) in diameter, with a flat surface for best performance.
For more detailed information: 3300 XL 8 mm Proximity Transducer System Datasheet