Product details
Overview
The Bently Nevada 330106-05-30-15-12-CN Reverse Mount Probe is engineered for precision in various industrial applications. Manufactured in the U.S.A, this probe stands out due to its robust design and reliability in extreme conditions. It is optimized for operations where accurate monitoring of rotational and vibration analysis is crucial.
Applications:
- Machinery monitoring in power plants
- Vibration analysis in rotating equipment
- Condition monitoring in industrial settings
Technical Specifications
- Brand: Bently Nevada
- Model: 330106-05-30-15-12-CN
- Suffix meanings:
- 330106-05-30: M10 x 1 threads
- 15: Total length of 1.5 meters (4.9 feet)
- 12: Connector option
- CN: Country-specific approval
Ordering Information
- Model: 330106-05-30
- Thread Size: M10 x 1
- Total Length: 15 (1.5 meters)
- Connector Option: Miniature ClickLoc coaxial connector, FluidLoc cable option
- Agency Approval: CN (Country Specific)
Dimensions
- Size: 20.4 cm x 22.2 cm x 3.7 cm
- Weight: 0.323 Kg
Electrical Specifications
- Nominal DC Resistance:
- Resistance (RPROBE): 7.73 ± 0.50 Ω
- Probe Length: 1.5 m
Mechanical Specifications
- Probe Tip Material: Polyphenylene sulfide (PPS)
- Probe Case Material: AISI 303 or 304 stainless steel (SST)
Torque Specifications
- Maximum Probe Torque: 22.6 N•m (200 in•lbf)
- Recommended Probe Torque: 7.5 N•m (66 in•lbf)
Thread Engagement
- Thread Size: M10 x 1
- Max Length of Thread Engagement: 15 mm
Temperature Range
- Operating & Storage: -52°C to +177°C (-62°F to +350°F)
- Extended Temperature Range:
- Tip: -52°C to +218°C (-62°F to +425°F)
- Cable & Connector: -51°C to +260°C (-60°F to +500°F)
Pressure Sealing
- Designed to seal differential pressure with a Viton® O ring. Probes are not pre-tested for pressure but can be specially tested upon request.
Relative Humidity Performance
- Exhibits less than a 3% change in Average Scale Factor (ASF) when tested at 93% humidity, adhering to IEC standard 68-2-3 for up to 56 days.
FAQ
Q: What is the maximum temperature capacity of this probe?
A: The standard probe operates up to 177°C, while the extended temperature range is rated for 218°C at the probe tip.
Q: Is the FluidLoc cable option necessary for all installations?
A: No, the FluidLoc cable is not required for the majority of installations due to the presence of the probe sleeve.
For more detailed information: 3300 XL 8 mm Proximity Transducer System Datasheet