Product details
Overview
The Bently Nevada 990 Vibration Transmitter (Product No. 990-10-XX-01-00) is an advanced, high-performance device designed for precise vibration measurement in industrial environments. Manufactured in the U.S.A., it provides a reliable solution for monitoring machinery health through vibration signals. The system is capable of handling a wide frequency range from 5 Hz to 6,000 Hz, offering superior accuracy in various applications. It is suitable for use in non-hazardous and hazardous (Zone 2 or Div 2) environments.
Key Features & Specifications
- Brand & Model: Bently Nevada, 990 Vibration Transmitter (990-10-XX-01-00)
- Full-Scale Option: 0-10 mils (0-250 Ī¼m pp)
- Mounting Option: 35 mm DIN rail clips (Option 01)
- Temperature Range: Operating: -35Ā°C to +85Ā°C (-31Ā°F to +185Ā°F), Storage: -52Ā°C to +100Ā°C (-62Ā°F to +212Ā°F)
- Probe Material: Polyphenylene sulfide (PPS) transducer tip; AISI 303 or 304 stainless steel (SST) for the probe case
- Cable: 75ā¦ coaxial cable, fluoroethylene propylene (FEP) insulated; Optional cable armor with flexible AISI 302 SST
- Agency Approval: No approval required (Option 00)
- Weight: 0.43 kg (0.9 lbm) for the transmitter; 0.82 kg total system weight
- Frequency Response: 5 Hz to 6,000 Hz (+0, -3 dB)
- Power Supply: +12 to +35 Vdc
- Signal Output: 4-20 mA over specified full-scale range in a 2-wire configuration
- Loop Resistance: Maximum of 1,000 ā¦, including cable at 35 Vdc
- Accuracy: Ā±1.5% over the specified full-scale range
- Probe Gap: 0.5 mm to 1.75 mm (20 to 55 mils)
FAQ
- What is the full-scale measurement range of the 990 Vibration Transmitter?
- The transmitter measures from 0-10 mils (0-250 Ī¼m pp) full scale.
- What is the maximum cable distance for the transmitter?
- The maximum cable distance for a proximitor sensor output is 3 meters (10 feet).
- What is the probe gap required for accurate measurements?
- The probe must be gapped between 0.5 mm and 1.75 mm (20 to 55 mils) from the target.
- What is the typical loop resistance limit?
- The maximum loop resistance is 1,000 ā¦ at 35 Vdc.
- What happens when a “Not OK” signal occurs?
- The signal output will drop to below 3.6 mA within 100 Āµs and will be restored within 2-3 seconds after the “Not OK” condition is resolved.
- Can the transmitter be used in hazardous areas?
- Yes, it is suitable for Zone 2 or Div 2 hazardous locations.
For more detailed information:990 Vibration Transmitter Datasheet
There are no reviews yet.